Industrial hygiene and safety assessment services for evaluating workplace air quality, chemical exposure, noise, heat stress, lighting, and personal exposure risks to support safe operations and regulatory compliance.

Tests We Perform

Indoor Air Quality (IAQ) Assessment

ISO 16000 Series, ASHRAE 62.1

Evaluates indoor air quality to ensure healthy workplaces and compliance with occupational standards.

Parameters: PM2.5, PM10, CO2, CO, TVOC, Temperature, Humidity, Air Velocity, Formaldehyde

Input: Occupied workspace TAT: 2-3 days

Similar Exposure Group (SEG) Assessment

ACGIH, AIHA Guidelines

Identifies worker exposure groups and evaluates occupational health risks based on similar work activities.

Parameters: Exposure Profile, Risk Classification, SEG Matrix

Input: Workplace assessment TAT: 3-5 days

Chemical Hazards Monitoring & Control Recommendations

OSHA, NIOSH, ACGIH TLVs

Monitors airborne chemical contaminants and recommends engineering and administrative controls to reduce exposure.

Parameters: Solvents, Acids, Alkalis, Gases, Vapours, Dust, Fumes

Input: Work area TAT: 3-5 days

Volatile Organic Compounds (VOC) Monitoring

ISO 16000-6, NIOSH Methods

Measures VOC concentrations in indoor and industrial environments to assess exposure and air quality.

Parameters: TVOC, Benzene, Toluene, Xylene, Ethylbenzene, Formaldehyde

Input: Work area TAT: 3-5 days

Leak Detection and Repair (LDAR) Survey

USEPA Method 21

Detects fugitive emissions from valves, flanges, pumps, compressors, and process equipment to reduce VOC emissions.

Parameters: VOC Leak Rate, Leak Inventory, Repair Recommendations

Input: Industrial facility TAT: 2-5 days

Occupational Noise Exposure Assessment

ISO 9612

Measures worker noise exposure and evaluates compliance with occupational exposure limits.

Parameters: LAeq, LEX,8h, Peak Noise Level

Input: Workplace TAT: 1-2 days

Heat Stress Assessment

ISO 7243

Evaluates workplace heat stress to protect workers in hot environments and improve safety.

Parameters: WBGT Index, Air Temperature, Humidity, Radiant Heat

Input: Workplace TAT: 1-2 days

Illumination (Lux) Survey

IS 3646, ISO 8995

Measures workplace lighting levels to ensure visual comfort, productivity, and safety compliance.

Parameters: Lux Level, Uniformity

Input: Work area TAT: 1 day

Personal Exposure Monitoring

NIOSH, OSHA Methods

Measures individual worker exposure to airborne contaminants using personal sampling equipment.

Parameters: Dust, Vapours, Gases, Metals, Solvents

Input: Selected employees TAT: 3-5 days

Respirable Dust & Silica Monitoring

NIOSH 7500

Determines worker exposure to respirable dust and crystalline silica in occupational environments.

Parameters: Respirable Dust, Crystalline Silica

Input: Workplace TAT: 3-5 days

Need testing for your project?

Get in touch with our certified engineers today to receive a customized quote.

Request a Quote